Rear View Mirror Removal
Rear View Mirror Installation
Mud Guard Installation
SidestandUpper Crankcase Assembly
When installing the breather plate, replace the gasket [A]
with a new one.
Apply a non-permanent locking agent to the threads of
the bolts [A] and tighten them.
Torque - Breather Plate Bolts: 9.8 N·m (1.0 kgf·m, 87 in·lb)
Install the fitting [A] until it is bottomed ...
DFI Servicing Precautions
There are a number of important precautions that should
be followed servicing the DFI system.
This DFI system is designed to be used with a 12 V sealed
battery as its power source. Do not use any other battery
except for a 12 V sealed battery as a power source.
Do not reverse the battery ...
Liquid Gasket, Non-permanent Locking Agent
For applications that require Liquid Gasket or a
Non-permanent Locking Agent, clean the surfaces so
that no oil residue remains before applying liquid gasket or
non-permanent locking agent. Do not apply them excessively.
Excessive application can clog oil passages and
cause serious damage.
...