Balancer Damper Inspection
Torque Limiter RemovalTechnical Information - Electronic Steering Damper (ESD/ZX1000JD/KD models)
1) Overview
This model has an Electronic Steering Damper (ESD)
[A]. Unlike conventional manual adjustment method of
Kawasaki, damping characteristics are adjusted by the
electronic control unit.
2) Purpose
Designed to offer increased stability at high speed without interfering with
light ...
Torque and Locking Agent
The following tables list the tightening torque for the major fasteners
requiring use of a
non-permanent locking agent or silicone sealant etc.
Letters used in the “Remarks� column mean:
AL: Tighten the two clamp bolts alternately two times to ensure even tightening
torque.
G: Apply ...
Connecting Rod Big End Side Clearance Inspection
Measure connecting rod big end side clearance.
Insert a thickness gauge [A] between the big end and either
crank web to determine clearance.
Connecting Rod Big End Side Clearance
Standard: 0.13 0.38 mm
(0.0051 0.0150 in.)
Service Limit: 0.58 mm (0.023 in.)
If the clearance exceeds ...