Kawasaki Ninja Service Manual: Output Fluid Pressure Sensor (Front Brake) Offset Abnormal (Service Code b 84)

Kawasaki Ninja Service Manual / Self-Diagnosis System / KIBS Service Codes (KIBS Equipped Models) / Output Fluid Pressure Sensor (Front Brake) Offset Abnormal (Service Code b 84)

The Output Fluid Pressure Sensor is built in the KIBS Hydraulic Unit. Therefore the sensor cannot be checked directly.

If this service code appears even if all checks are ended, replace the KIBS hydraulic unit.

If the service code does not appear, the KIBS system normal (temporary failure).

Output Fluid Pressure Sensor (Front Brake) Wiring Inspection (Service Code b 83)
The Output Fluid Pressure Sensor is built in the KIBS Hydraulic Unit. Therefore the sensor cannot be checked directly. Perform the Pre-Diagnosis Inspection 1 and 2 (see Inquiries to Rider in th ...

Fluid Pressure Sensor Supply Voltage Inspection (Service Code b 89)
The Fluid Pressure Sensors are built in the KIBS Hydraulic Unit. Therefore the voltage cannot be checked directly. Perform the Pre-Diagnosis Inspection 1 and 2 (see Inquiries to Rider in the B ...

Other materials:

Wheel/Tire Damage Inspection
Remove any imbedded stones [A] or other foreign particles [B] from tread. Visually inspect the tire for cracks and cuts, and replace the tire if necessary. Swelling or high spots indicate internal damage, requiring tire replacement. Visually inspect the wheel for cracks, cuts and dents ...

Camshaft, Camshaft Cap Wear Inspection
Remove the camshaft caps (see Camshaft Removal). Cut the strips of plastigage (press gauge) to journal width. Place a strip on each journal parallel to the camshaft installed in the correct position. Tighten the camshaft cap bolts and upper camshaft chain guide bolts to the specified ...

Rear Wheel Rotation Sensor Signal Abnormal (Service Code b 44)
Measure the air gap between the rear wheel rotation sensor and sensor rotor. Thickness Gauge [A] Air Gap Standard: 0.4 1.6 mm (0.02 0.06 in.) If the measurement is not the standard, check each part for deformation and looseness and correct accordingly. If the measurement is the sta ...