If any plate is warped over the service limit, replace it with a new one.
Friction and Steel Plate Warp
Standard: 0.15 mm (0.0059 in.) or less
Service Limit: 0.3 mm (0.012 in.)
Water Pump Housing Assembly
NOTICE
Do not reuse the mechanical seal and oil seal.
Apply high-temperature grease to the new oil seal lips [A].
Press the new oil seal into the housing with a bearing
driver [B] until it stops at the bottom surface [C] of the
housing.
Special Tool - Bearing Driver Set: 57001-1129
...
Tie-Rod and Rocker Arm Bearing Installation
Replace the needle bearings [A] and oil seals with new
ones.
Apply plenty of grease to the lips of the oil seals.
Install the needle bearings and oil seals position as shown
in the figure.
Screw the needle bearing driver into the driver holder.
Insert the needle bearing driver into th ...
Stator Coil Installation
Apply a non-permanent locking agent to the threads of
the stator coil bolts and tighten them.
Torque - Stator Coil Bolts: 12 N·m (1.2 kgf·m, 106 in·lb)
Using a high flash-point solvent, clean off any oil or dirt
that may be on the silicone sealant coating area. Dry
them with a clea ...