Brake Hose
Parts LocationKIBS Servicing Precautions
There are a number of important precautions that should
be followed servicing the KIBS.
This KIBS is designed to be used with a 12 V sealed battery
as its power source. Do not use any other battery
except for a 12 V sealed battery as a power source.
Do not reverse the battery cable connec ...
Armature Inspection
Using the × 1 Ω hand tester range, measure the resistance
between any two commutator segments [A].
Special Tool - Hand Tester: 57001-1394
If there is a high resistance or no reading (∞) between any
two segments, a winding is open and the starter motor
must be replaced.
...
Piston Installation
Apply molybdenum disulfide oil solution to the oil ring expander,
and install the oil ring expander [A] in the bottom
piston ring groove so the ends [B] not butt together
Applymolybdenum disulfide oil solution to the oil ring steel
rails, and install the oil ring steel rails, one above th ...